Transformers Oil Testing (NABL Accredited) Services

Our Transformer Oil Testing Services are conducted with utmost precision and adherence to industry standards, ensuring the safety and longevity of your transformers. Accredited by NABL, we offer comprehensive testing to evaluate the physical, chemical, and electrical properties of transformer oil, as well as insights into the internal condition of the transformer. Our testing services help detect potential issues early and prevent transformer failures.

Physical Parameters

  1. Appearance
    • Inspection of oil clarity and color to detect contamination or degradation.
  2. Interfacial Tension
    • Measures the tension between oil and water, providing insight into oil quality.
  3. Flash Point
    • Tests the temperature at which the oil vaporizes and can ignite.
  4. Pour Point
    • Determines the lowest temperature at which oil remains fluid, indicating low-temperature performance.
  5. Density
    • Measurement of oil density to assess purity and consistency.
  6. Kinematic Viscosity
    • Measures the oil’s resistance to flow at different temperatures, indicating its ability to lubricate and insulate.

Chemical Parameters

  1. Water Content
    • Detects moisture levels in the oil, which can cause insulation breakdown.
  2. Total Acid Number / Neutralization Value
    • Measures the acid content in the oil, helping assess the degree of degradation.
  3. Sediments and Sludge

Identifies impurities, such as solid particles or sludge, that can harm transformer components.

Electrical Parameters

  1. Breakdown Voltage / Dielectric Strength
    • Evaluates the oil’s ability to withstand electrical stress without breaking down.
  2. Specific Resistance / Resistivity
    • Measures the resistance to electrical flow, indicating insulation integrity.
  3. Dielectric Dissipation Factor / Tan Delta

Assesses the oil’s ability to insulate by measuring energy loss in the system.

Transformer Internal Condition

  1. Dissolved Gas Analysis (DGA)
    • Identifies the presence of dissolved gases in the oil, which can indicate fault conditions such as arcing or overheating.

Transformer Insulating Paper Condition

  1. Furanic Compound Analysis (Furans)
    • Detects furans, which are byproducts of paper insulation degradation, helping assess transformer health.

Other Special Tests

  • Customized testing as per customer requirements for unique transformer conditions and specifications.

Testing Packages as per Industry Standards

Our oil testing services are aligned with the following standards:

  • IS (Indian Standards)
  • IEC (International Electrotechnical Commission)
  • ASTM (American Society for Testing and Materials)

Our Transformer Oil Testing Services are conducted with utmost precision and adherence to industry standards, ensuring the safety and longevity of your transformers. Accredited by NABL, we offer comprehensive testing to evaluate the physical, chemical, and electrical properties of transformer oil, as well as insights into the internal condition of the transformer. Our testing services help detect potential issues early and prevent transformer failures.

Physical Parameters

  1. Appearance
    • Inspection of oil clarity and color to detect contamination or degradation.
  2. Interfacial Tension
    • Measures the tension between oil and water, providing insight into oil quality.
  3. Flash Point
    • Tests the temperature at which the oil vaporizes and can ignite.
  4. Pour Point
    • Determines the lowest temperature at which oil remains fluid, indicating low-temperature performance.
  5. Density
    • Measurement of oil density to assess purity and consistency.
  6. Kinematic Viscosity
    • Measures the oil’s resistance to flow at different temperatures, indicating its ability to lubricate and insulate.

Chemical Parameters

  1. Water Content
    • Detects moisture levels in the oil, which can cause insulation breakdown.
  2. Total Acid Number / Neutralization Value
    • Measures the acid content in the oil, helping assess the degree of degradation.
  3. Sediments and Sludge
    • Identifies impurities, such as solid particles or sludge, that can harm transformer components.

Electrical Parameters

  1. Breakdown Voltage / Dielectric Strength
    • Evaluates the oil’s ability to withstand electrical stress without breaking down.
  2. Specific Resistance / Resistivity
    • Measures the resistance to electrical flow, indicating insulation integrity.
  3. Dielectric Dissipation Factor / Tan Delta
    • Assesses the oil’s ability to insulate by measuring energy loss in the system.

Transformer Internal Condition

  1. Dissolved Gas Analysis (DGA)
    • Identifies the presence of dissolved gases in the oil, which can indicate fault conditions such as arcing or overheating.

Transformer Insulating Paper Condition

  1. Furanic Compound Analysis (Furans)
    • Detects furans, which are byproducts of paper insulation degradation, helping assess transformer health.

Other Special Tests

  • Customized testing as per customer requirements for unique transformer conditions and specifications.

Testing Packages as per Industry Standards

Our oil testing services are aligned with the following standards:

  • IS (Indian Standards)
  • IEC (International Electrotechnical Commission)
  • ASTM (American Society for Testing and Materials)

The Erection & Commissioning Service is conceptually used in the installation process of several industrial plants. We are backed by a team of adroit personnel who render these services in the most efficient way within the postulated time frame. Also, these services are greatly appreciated by our patrons for their nimbleness. We offer ETC services for Transformer/Reactor/CT/PT/CVT having various ratings. We have rich domain expertise and dedicated manpower for the erection of small to higher rating Transformers. We follow all the safety standards with the consent of the customer to avoid any minor or major incidents. After the completion of ETC work, a certificate will be provided ensuring the installations are done perfectly.

Testing is extremely essential for preventive as well as breakdown maintenance. Excellent Diagnostic and Research Agency has a dedicated testing team furnished with advanced instruments, which conducts tests with accuracy, reliability, and repeatability. The teams are well trained and equipped to thoroughly and reliably test all kinds of installations in a switchyard and transmission lines. 

Sub-station classes

  • 765 kV
  • 400 kV
  • 220 kV
  • 132 kV
  • 66 kV
  • 33 kV
  • 11 kV
  • 6.6 kV

Highly
Reliable

Quality
Assurance

Competent
pricesHighly

Precise
installation

Customer
satisfaction

The Entire Process

Pre-erection activities are completed before starting erection

Erection of built-in parts of the plant

Erection of the main operating components

  1. Erection is similar to installation however erection is to install something piece by piece that rises up.
  2. Commissioning is bringing the installed thing into running as per the required professional standards.
  3. Testing means to confirm the installed device is running with complete functionality and it is delivering the required output.
Pre-erection activities
  • Preparation of a plan for the implementation of erection work and sequence of various activities
  • Site storage planning consists of open, locked, semi-closed storage and road construction, connection for plant distribution to assembly field.
  • Erection of temporary structures, living quarters needed to work smoothly and quickly on the site.
  • Building power, water, compressed air system for erection operations. DG sets of sufficient capacity to be retained when a power failure occurs.
  • Arrangement of lighting of erection site and nearby area.
  • Ensure the timely supply of equipment and materials needed for the continuation of erection work in conjunction with charts and schedules.
  • Providing installation plans for hoisting, carrying systems, instruments, and equipment as well as coordinating the transfer of material to the site. The content will be removed and transferred to a pre-identified position in the unloading port.
  • Arrangement of protective measures to protect workers and machinery during the storage, transport, and deployment of various plant components.
  • In the first point, a well-coordinated overall plan is planned for the development of civil works and activities related to the building of hydro-mechanical and hydro-generating systems.

  • A PERT / CPM shall be established to track current operations and sensitive activities in order to prevent any interruption in the plan.

  • The number of building works to be finished by months in keeping with the project’s total planned construction timetable.

  • Big activity-wise PERTs are established displaying sequence and length of activities matching delivery schedule and civil building activities to track erection works in charge. This should provide a timeline and length as per the total timetable of all essential and concurrent tasks to complete the erection work.

SECTORS WE SERVE

  • Power​ | Utility
  • Oil & Gas​ | Petrochemical
  • Fertilizer & Chemicals
  • Steel ​| Cement
  • Mining​  | Pharmacy
  • Metro​ | Airport​ | Seaport​​

WHY ?

  • Excellent Diagnostic and Research Agency products and services are required WHY for

    • Assessing the Plant Equipment Health.​​
    • For Plant Equipment preventive care.
    • For Keeping Plant equipment performance history.

WHERE ?

  • Excellent Diagnostic and Research Agency products and services are required, WHEREequipment like HV Transformers, HV Motors, TG’s are available and in operation in Plant. ​Excellent Diagnostic and Research Agency would add value to its clients for 

    • Plant equipment condition monitoring and reliability studies are to be done.
    • Keeping track of the history of plant equipment.
    • For providing professional advice on plant asset health, reliability, and sustainability.

WHEN ?

  • Excellent Diagnostic and Research Agency products and services are required WHEN  Plant equipment is under break down.

    • Plant Equipment is under  Periodic Maintenance period, Plant shutdowns, Plant start-ups, Annual maintenance.​​
    • Emergency repairs.
    • During Plant equipment abnormal operation.